Към съдържанието
Автомат DPX3 630 TM 3P 400A 70кA регулируем (In x 0.8...1) Legrand

Автомат DPX3 630 TM 3P 320A 70кA регулируем (In x 0.8...1) Legrand
Автомат DPX3 630 TM 3P 320A 70кA регулируем (In x 0.8...1) Legrand
Вход за да видите цената
Автомат DPX3 630 TM 3P 500A 70кA регулируем (In x 0.8...1) Legrand
Автомат DPX3 630 TM 3P 500A 70кA регулируем (In x 0.8...1) Legrand
Вход за да видите цената

Автомат DPX3 630 TM 3P 400A 70кA регулируем (In x 0.8...1) Legrand

Модел: LG-422030
https://b2b.sectron.com/web/image/product.template/49771/image_1920?unique=a99e839

Вход за да видите цената

Само по запитване
(0,00 € / бр.)

  • Вид продукт
  • Вид продукт
  • Ниво на защита IP
  • Number of poles
  • Type of electrical connection of main circuit
  • Type of control element
  • Rated permanent current Iu
  • Adjustment range undelayed short-circuit release
  • With integrated under voltage release
  • Device construction
  • Overload release current setting
  • Motor drive integrated
  • Motor drive optional
  • Number of auxiliary contacts as change-over contact
  • Integrated earth fault protection
  • Suitable for DIN rail (top hat rail) mounting
  • Rated short-circuit breaking capacity Icu at 400 V, 50 Hz
  • With switched-off indicator
  • Position of connection for main current circuit
  • Rated voltage
  • DIN rail (top hat rail) mounting optional
  • Complete device with protection unit

Тази комбинация не съществува.

Вид продукт Автоматичен прекъсвач, Автоматичен прекъсвач
Ниво на защита IP IP30
Number of poles 3
Type of electrical connection of main circuit Screw connection
Type of control element Wing knob
Rated permanent current Iu 400 A
Adjustment range undelayed short-circuit release 2000 … 4000 A
With integrated under voltage release Да
Device construction Built-in device fixed built-in technique
Overload release current setting 320 … 400 A
Motor drive integrated Не
Motor drive optional Да
Number of auxiliary contacts as change-over contact 2
Integrated earth fault protection Не
Suitable for DIN rail (top hat rail) mounting Не
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz 70 kA
With switched-off indicator Да
Position of connection for main current circuit Front side
Rated voltage 220 … 690 V
DIN rail (top hat rail) mounting optional Не
Complete device with protection unit Да
3D_422032.dwg
Изтегли
EXB25005-03-2025.pdf
Изтегли
F01958EN/06.pdf
Изтегли
LE07062AB.pdf
Изтегли
LGGANEQZVZ.pdf
Изтегли
LGRP-00702-V01.01-EN.pdf
Изтегли
LGRP-02223-V01.01-EN.pdf
Изтегли
LGYCMCSNJO.pdf
Изтегли